What conditions will cause the cooling and heating functions of DJI Dock 3 to be automatically enabled or disabled?
DJI Dock 3’s cooling activates when the ambient temperature is above 5°C (41°F) and the aircraft battery exceeds 35°C (95°F). It turns off once the battery cools below 30°C (86°F).
Heating activates when the ambient temperature is below 5°C (41°F), the dock’s internal temperature is under 35°C (95°F), and the battery is also below 35°C (95°F). Heating stops when either the dock or battery temperature exceeds 35°C (95°F).
Cooling and heating behaviour may change with firmware updates—refer to actual performance during use.